Computerized planar tomography system for diagnostics of combat injuries
DOI:
https://doi.org/10.18372/2073-4751.81.20139Keywords:
radiography, digital tomosynthesis, tomography, contrast, image, phantomAbstract
In this work, the use of mobile digital X-ray tomosynthesis complexes for diagnosis of shrapnel wounds in front-line hospitals was substantiated. During the research, an increase in the contrast of pathological images by 6...8 times was experimentally obtained in mobile X-ray complexes with tomographic information technology compared to X-ray images. A modeling stand was created in which a working sample of a veterinary mobile device with tomosynthesis was used and a measuring phantom was developed that simulates shrapnel lesions of the extremities. This made it possible to obtain reliable measurement results.
References
Воєнно-польова хірургія. за ред. Я. Л. Заруцького, В. Я. Білого. Київ : Фенікс, 2018. 552 с.
Носов А. А., Мірошниченко С., Коваленко Ю. М. Цифрові рентгенівські технології допомагають рятувати життя пораненим бійцям. Радіологічний вісник. 2014 № 3. С. 9–12.
WHO consolidated guidelines on tuberculosis: module 2: screening: systematic screening for tuberculosis disease. URL: https://www.who.int/publications/i/item/9789240022676.
Мірошниченко С. І., Уріна Л. К. Томосинтез на базовій рнтгенодіагностичної системі. Київ : Медицина України, 2019. 40 с.
ST-14770-2022-INIT en. Council Recommendation on strengthening prevention through early detection: A new EU approach on cancer screening replacing Council Recommendation 2003/878/EC.
Miroshnychenko O. et al. Assessment of Compliance Digital X-ray Tomosynthesis Images of Chest with the Requirements for the Tomographic Images Quality. 2022 IEEE 41st International Conference on Electronics and Nanotechnology (ELNANO) : proceedings, Kyiv, Ukraine, 10–14 October 2022 / IEEE. 2022. P. 401–404. DOI: 10.1109/ELNANO54667.2022.9927068.
Miroshnychenko O. et al. Contrasts comparison of the same cases of chest pathologies for radiography and tomosynthesis. 2020 International Symposium on Electronics and Telecommunications (ISETC), Timisoara, Romania, 05–06 November 2020 / IEEE. 2020. P. 1–4. DOI: 10.1109/ISETC50328.2020.9301081.
Downloads
Published
How to Cite
Issue
Section
License
The scientific journal adheres to the principles of Open Access and provides free, immediate, and permanent access to all published materials without financial, technical, or legal barriers for readers.
All articles are published in Open Access under the Creative Commons Attribution 4.0 International (CC BY 4.0) license.
Copyright
Authors who publish their works in the journal:
-
retain the copyright to their publications;
-
grant the journal the right of first publication of the article;
-
agree to the distribution of their materials under the CC BY 4.0 license;
-
have the right to reuse, archive, and distribute their works (including in institutional and subject repositories), provided that proper reference is made to the original publication in the journal.